Production: streams audio to VAPI with the senior-auditor prompt and streams structured observations back. Here we latch a sample transcript so the UI and compliance engine behave identically.
Observations — Bayside Tower — Condo Milestone
2 total
  • significantSpalling at perimeter slab edge, Level 8manual
    Level 8, NE corner, grid B-4 to B-5

    Observed spall approximately 250 mm wide exposing corroded reinforcing bar at slab edge. Section loss on exposed bar visually estimated at 10-15%. Surrounding concrete shows chloride staining consistent with coastal exposure.

    ACI 318 Ch. 26FBC 1609.1.2FBC-HVHZ 1620IBC Chapter 17
    2 media
  • moderateHairline crack pattern, south stair core wallvoice capture
    South stair, Level 3, east face

    Vertical hairline cracks spaced 300-400 mm apart across CMU wall, widths below 0.3 mm. No displacement observed. Appears consistent with long-term shrinkage; no active monitoring in place.

    Field data gaps
    • Record crack width in mm or inches and note active vs dormant.
    FBC-HVHZ 1620IBC Chapter 17ACI 318 Ch. 26
    1 media
Asset summary
Bayside Tower — Condo Milestone
2250 NE Ocean Blvd, Fort Lauderdale, FL
milestone inspectioncondo towerBuilt 1983
Capture tips
  • Always include a grid line or elevation in the location.
  • Record crack widths in mm or inches.
  • Attach a scale-reference photo for spalls.
  • Note chloride/salt exposure for coastal assets.
  • Voice captures still require photo evidence.