Field capture
Record an observation
Manual entry or simulated voice capture. Both route through the compliance engine for missing-data prompts.
Manual capture
Inspector-authored narrative. Attaches a photo metadata record.
Voice capture (simulated)
Runs the senior-auditor VAPI prompt and returns a transcript, suggested title, and severity inference.
Production: streams audio to VAPI with the senior-auditor prompt and streams structured observations back. Here we latch a sample transcript so the UI and compliance engine behave identically.
Observations — Bayside Tower — Condo Milestone
2 total
- significantSpalling at perimeter slab edge, Level 8manualLevel 8, NE corner, grid B-4 to B-5
Observed spall approximately 250 mm wide exposing corroded reinforcing bar at slab edge. Section loss on exposed bar visually estimated at 10-15%. Surrounding concrete shows chloride staining consistent with coastal exposure.
ACI 318 Ch. 26FBC 1609.1.2FBC-HVHZ 1620IBC Chapter 172 media - moderateHairline crack pattern, south stair core wallvoice captureSouth stair, Level 3, east face
Vertical hairline cracks spaced 300-400 mm apart across CMU wall, widths below 0.3 mm. No displacement observed. Appears consistent with long-term shrinkage; no active monitoring in place.
Field data gaps- Record crack width in mm or inches and note active vs dormant.
FBC-HVHZ 1620IBC Chapter 17ACI 318 Ch. 261 media
Asset summary
Bayside Tower — Condo Milestone
2250 NE Ocean Blvd, Fort Lauderdale, FL
milestone inspectioncondo towerBuilt 1983
Site contact
Lourdes Caro · Association property manager
Capture tips
- Always include a grid line or elevation in the location.
- Record crack widths in mm or inches.
- Attach a scale-reference photo for spalls.
- Note chloride/salt exposure for coastal assets.
- Voice captures still require photo evidence.